Fire damage is expensive no matter where it rears its ugly head. Manufacturing plants and fulfillment centers are no exception.
Fires are a serious safety concern, destroy product, create the need for expensive equipment repairs, and result in expensive downtime, and delays in meeting customer delivery requirements. Conveyor systems accelerate the risk of fire damage because fire can be conveyed throughout the plant at very high rates of speed. It is estimated that the average insurance claim for a conveyor belt related fire exceeds $8 million dollars.
The most common cause of fire on a belt is the friction generated from a pulley on a stalled or slipping conveyor belt. Seized idlers and bearings also generate enough heat on the back of a moving belt to ignite fires. The second cause of fires started with conveyor belts is due to mistracking. Friction from the belt rubbing on the conveyor can be enough to ignite. Manufacturing facilities with combustible materials that build up on their conveyor beds such as cardboard, oils, chemicals, and dust are highly susceptible to spontaneous combustion from the heat generated in these conditions.
Unfortunately, environments that leave manufacturing plants vulnerable to fire damage are common and sometimes impossible to avoid. Sparks has developed a wide range of fire-retardant or FR conveyor belts that adhere to ASTM D-378 standards to lower your risk. When properly tested, these belts self-extinguish in less than one minute and the incandescence cannot last more than an average of three minutes.
Where would we recommend using fire retardant belts?
Our highly trained sales team offers an extra set of eyes and ears on your equipment. Regular walkthroughs give us the opportunity to conduct regular belt and conveyor visual audits. If there are conditions present that are a fire hazard, we will bring that to your attention and allow your team to:
Sparks offers a wide range of belt constructions and cover surfaces with industry-proven fire-retardant additives. These belts regularly operate in demanding environments. If safety is a concern in your facility, reach out to Sparks and we will be happy to fit your plant with fire retardant belts in critical applications to minimize your risk of fire damage.
EN Category 1. EN contains the standards for electrical and flammability safety requirements for general purpose conveyors used above ground. Category 1 is the most basic classification and simply demands that the belt is anti-static. This means that the belt meets the primary requirement for use in ATEX 114 (Directive /34/EU) classified zones if necessary.
Goto Bluemaxim to know more.
Application: In environments where coal dust, fertilizer, grain or other potentially combustible materials such as biomass are present, it is essential that the conveyor belt cannot create static electricity that could ignite the atmosphere. Belts need to be able to allow static electricity to pass through the metal frame of the conveyor structure down to earth rather than allow static to build up. The safest approach is for all belts to meet EN Category 1.
The basis of most tests within EN for belting actual fire resistance is EN ISO 340*. These standards make the distinction between fire resistance with covers, which is Class 2A (often referred to as K grade) and fire resistance with and without covers, which is Class 2B (often referred to as S grade). The relevance of with and without covers is primarily because the rubber skim layers between the synthetic plies protect what is essentially the most flammable part in the construction and which can provide the path for flames to propagate. The rubber skim material therefore needs to be as equally fire resistant as the outer covers. Unfortunately, manufacturers who want to minimise costs to achieve a more competitive price often use rubber skims that have insufficient resistance to fire and/or are too thin.
*EN ISO 340 tests involve exposing six individual samples of belt to a naked flame causing them to burn. The source of the flame is then removed and the combustion time (duration of flame) of the test piece is recorded. A current of air is then applied to the test piece for a specified time after the removal of the flame. The flame should not re-ignite.The time it takes for the belt sample to self-extinguish after the flame has been removed is measured. The duration of continued burning (visible flame) should be less than 15 seconds for each sample with a maximum cumulative duration of 45 seconds for each group of six tests. The average allowable time per sample is therefore 7.5 seconds. This factor is crucial because it determines the distance that the fire can be effectively carried by a moving belt. For this reason, Fenner Dunlop in The Netherlands strive for an average maximum time limit of only one second, which is more than six times faster than the required standard.
Application: For the majority of bulk material handling open air applications, EN Class 2A (K grade) or Class 2B (S grade) levels of fire resistance would be perfectly adequate. The best way to decide between Class 2A and Class 2B is to consider the material being carried. For moderately abrasive materials such as grain, then Class 2A is usually suitable. However, if the material is more abrasive and tends to wear the top cover more rapidly and/or you would prefer a higher level of fire safety then the safest option is to choose Class 2B.
Class 2A is usually perfectly adequate for moderately abrasive materials such as grain.Class 4A involves a more severe fire test according to EN -1 method A, C or D in addition to EN ISO 340 testing.
Application: This increased level of fire safety is particularly necessary when conveying biomass because the dry flammable dust found in biomass can be ignited by static electricity created by abrasion within the conveyor system because the source only requires ignition energy as low as 17mJ for ignition to take place. Biomass dust is also prone to self-ignition, especially if it becomes damp. A chemical reaction can take place that causes self-heating and what is referred to as off-gassing (carbon dioxide, carbon monoxide and methane emissions).
Class 4A involves a more severe fire test according to EN -1 method A, C or DAlthough the use of covered conveyors minimizes this risk, the risk to human life is heightened in enclosed environments because burning rubber belts release thick toxic smoke that contains cyanide, carbon monoxide, sulfur dioxide, and products of butadiene and styrene. EN Class 4A is therefore usually also the best choice for conveyors operating in closed or covered conditions
Experience shows, without doubt, that the price will invariably be reflected in its overall performance including its ability to self-extinguish fire in good time. The low prices may be very tempting, but it is important to understand how those prices are achieved. The true reason is that raw materials, including the expensive chemicals needed to create rubber that has a good standard of resistance to fire, represent up to 70% of the cost of producing a conveyor belt. Consequently, the only way to manufacture a low-price belt is to use (or omit altogether) low grade raw materials and essential additives. There simply is no other way. The price of an insufficiently fire-resistant conveyor belt cannot be calculated. It really is a matter of life and death.